Fluke ESA609 115 VAC Electrical Safety Analyzer

$1,694.00
In stock
SKU
EV5194
Model:
  ESA609
Product Condition:
  Refurbished

This is a like new Fluke ESA609 115 VAC Electrical Safety Analyzer that is tested and working.

Looking to sell your equipment? Get a quick offer on your new & used test equipment, XRF, analyzer, utility locator etc. Sell to Us

Product Overview

Fluke ESA609 115 VAC Electrical Safety Analyzer

This is a like new Fluke ESA609 115 VAC Electrical Safety Analyzer that is tested and working.

Includes:

  • Fluke ESA609 Electrical Safety Analyzer
  • (2) Fluke Flexible Test Leads
  • (2) Test Pins
  • (1) Alligator Clips (Black)
  • Power Cord
  • Carrying Case

Fluke ESA609 Safety Analyzer

The on-the-go analyzer
The ESA609 Electrical Safety Analyzer is a rugged, portable and easy-to-use analyzer designed for general electrical safety testing. Engineered for onthe-go technicians, the ESA609 requires no training to use and has a rubberized case that allows it to sustain the rigor of transportation, and helps prevent damage when accidentally dropped. Additionally, its functional strap and featherweight design make it one of the most portable electrical safety analyzers in its class. Heavy-duty switches allow users to effortlessly change polarity and configuration of the neutral connection between open and closed, while push-button operation ensures fast transition between tests for complete basic testing in minutes. The ESA609 integrates all functions needed to test medical devices when patient lead testing is not required, including: line (mains) voltage, ground wire (protective earth) resistance, equipment current, leakage current and point-to point tests. Versatile to global electrical safety standards of choice, the ESA609 tests to ANSI/AAMI ES1, NFPA-99, and parts of IEC62353 and IEC60601-1.

Features:

  • Compliant standards include: ANSI/AAMI ES1, NFPA-99, and parts of IEC62353 and IEC60601-1
  • Test current consumption up to 20 A for a diverse set of medical devices
  • All parameters needed for basic electrical safety testing: Line (mains) voltage, ground wire (or protective earth) resistance, equipment current, ground wire (earth) leakage, chassis (enclosure) leakage, direct equipment leakage, and point to point leakage and resistance
  • Global use: the ESA609 will operate at 120 V and 230 V
  • Rugged: Built tough with a rubberized case and ingress protection rating of IP30
  • User-friendly: Quick push-button operation for rapid testing
  • Portable: Featherweight (1.5 lb) design, functional strap, and tilt stand make it easy for transportation and operation on-the-go (onsite or offsite)
  • Rigorously tested for safety and reliability, with CE, CSA and Australia RCM in addition to Fluke quality

Specifications:

Test standard selections ANSI/AAMI ES-1/NFPA99, IEC62353, IEC60601-1
Mains voltage measurement
Range 90.0 to 264.0 V ac rms
Accuracy ± (2 % of reading + 0.2 V)
Earth resistance
Modes Two wire
Test current > 200 mA dc
Range 0.000 Ω to 20.000 Ω
Accuracy ± (1 % of reading + 0.010 Ω)
Resistance tests Earth resistance and point to point
Equipment current
Mode AC RMS
Range 0.0 A to 20.0 A
Accuracy ± (5 % of reading + (2 counts or 0.2 A, whichever is greater))
Duty cycle 15 A to 20 A, 5 min on / 5 min off 10 A to 15 A, 7 min on / 3 min off 0 A to 10 A, continuous
Leakage current
Modes True-RMS
Patient load selection AAMI ES1-1993 Fig. 1 IEC 60601: Fig. 15
Crest factor Less than or equal to 3
Ranges 0.0 µA to 1999.9 µA Accuracy
DC to 1 kHz ± (1 % of reading + (1 µA , whichever is greater))
1 kHz to 100 kHz ± (2.5 % of reading + (1 µA, whichever is greater))
100 kHz to 1 MHz ± (5 % of reading + (1 µA, whichever is greater))
Leakage tests Ground wire earth
Chassis (enclosure)
Direct equipment
Point to point
Temperature
Operating 0 °C to 50 °C (32 °F to 122 °F)
Storage -20 °C to 60 °C (-4 °F to 140 °F)
Humidity 10 % to 90 % non-condensing
Altitude
120 V ac mains supply voltage 5000 m
230 V ac mains supply voltage 2000 m
Display LCD display
Modes of operation Manual
Power ratings
115 volt power outlet 90 to 132 V ac rms, 47 to 63 Hz, 20 A maximum
230 volt power outlet 180 to 264 V ac rms, 47 to 63 Hz, 16 A maximum
Power input 115 V 20 A - 2.6 kVA and 230 V at 16 A - 4.2 kVA
Physical case
Weight 0.7 kg (1.5 lb)
Dimensions 22.9 cm x 17.8 cm x 6.4 cm (9 in x 7 in x 2.5 in)
Safety IEC 61010-1: Overvoltage Category II, Measurement 300 V CAT II, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Emissions classification IEC CISPR 11: Group 1, Class A.

 

Specifications

Weight 7 lbs
Brand Fluke Networks
MPN EV5194
Model ESA609
Product Condition Refurbished

What's in the box?

  • Fluke ESA609 Electrical Safety Analyzer
  • (2) Fluke Flexible Test Leads
  • (2) Test Pins
  • (1) Alligator Clips (Black)
  • Power Cord
  • Carrying Case